MS-FAC2612-1 Johnson Controls Application Field Equipment Controller (FAC)

MS-FAC2612-1 Johnson Controls Advanced Application Field Equipment Controller (FAC)

MS-FAC2612-1 Johnson Controls Advanced Application Field Equipment Controller (FAC)


 

Advanced Application Field Equipment Controller (FAC) The Advanced Application Field Equipment Controller (FAC) Series Controllers are programmable controllers that can communicate using BACnet® Secure Connect (BACnet/SC), BACnet/IP, MS/TP, or N2 communications protocols, depending on the model. The FAC4911 is a BACnet Advanced Application Controller (B-AAC) that communicates using BACnet/IP or BACnet/SC communications protocol. All other FAC Series controllers, except the FAC4911, can be switched between MS/TP and N2 communication protocols. FAC controllers used as MS/TP devices are B-AACs with integral RS-485 MS/TP communication.

FAC Series Controllers feature an integral realtime clock. FACs support time-based tasks and maintain time-based control, which enables these field controllers to monitor and control schedules, calendars, alarms, and trends. FACs can continue time-based control and monitoring when offline for extended periods of time from a Metasys system network.

FAC Series Controllers can also operate as standalone controllers in applications that do not require a networked supervisory device or for network applications where it is preferred to have the scheduling, alarming, and/or trending performed locally in the field controllers.

 


 

Features

⇒ Standard BACnet Protocol

Provides interoperability with other Building Automation System (BAS) products that use the widely accepted BACnet standard.

⇒ Switchable Communications Protocols

Provides flexibility with a choice between BACnet MS/TP and N2 communication.

⇒ Model to support BACnet/SC and BACnet/IP communications

FAC4911 controllers provide higher speed communication with the Controller Configuration Tool (CCT) and improved bandwidth. BACnet/SC is a new protocol that provides a secure method of communication on IP networks. It uses standards widely accepted by the IT community, eliminating many of the IT community’s concerns.

⇒ Standard Hardware and Software Platform

Uses a common hardware design throughout the family line to support standardized wiring practices and installation workflows; also uses a common software design to support use of a single tool for control applications, commissioning, and troubleshooting to minimize technical training.

⇒ Wireless ZFR and ZFR Pro support

Wireless ZFR and ZFR Pro support provides a wireless alternative to hard-wired MS/TP networking, offering application flexibility and mobility with minimal disruption to building occupants, and also simplifies and speeds up replacements.

⇒ Auto-Tuned Control Loops

Proportional Adaptive Control (P-Adaptive) and Pattern Recognition Adaptive Control (PRAC) deliver continuous control loop tuning, which reduces commissioning time, eliminates change-of-season recommissioning, and reduces wear and tear on actuators.

⇒ Integral real-time clock

Controllers use an integral real-time clock to monitor and control schedules, calendars, and trends, and operate for extended periods of time as stand-alone controllers when offline from the Metasys system network.

⇒ Universal Inputs and Configurable Outputs

Allows multiple signal options to provide input/ output flexibility.

⇒ BACnet Testing Laboratories (BTL) Listed and Certified

Ensures interoperability with other BTL-listed devices. BTL is a third-party agency, which validates that BAS vendor products meet the BACnet industrystandard protocol.

⇒ BACnet Automatic Discovery

Supports easy controller integration into a Metasys BAS.

⇒ End-of-Line (EOL) Switch in MS/TP Field Controllers

Enables field controllers to be terminating devices on the communications bus.

⇒ Pluggable Communications Bus and Supply Power Terminal Blocks

Expedites installation and troubleshooting.

⇒ Writable Flash Memory

Allows standard or customized applications to be downloaded from the CCT and enables persistent application data.

⇒ Local Controller Display and the MAP Gateway Support

Enable monitoring and commanding of I/O and configuration parameters

 


FAC series model information

FAC ⇓

Series model ⇒

FAC2513 FAC2611 FAC2612 FAC3613 FAC4911
Point types Signals accepted 4 Current Mode not supported 6 5 8 10
Universal Input (UI) Analog Input, Voltage Mode, 0– 10 VDC Analog Input, Current Mode, 4–20 mA Analog Input, Resistive Mode, 0–2k ohm, RTD (1k NI [Johnson Controls], 1k PT, A99B SI), NTC (10k Type L, 2.252k Type 2) Binary Input, Dry Contact Maintained Mode 6 2 4 6 6
Binary Input (BI) Dry Contact Maintained Mode Pulse Counter/Accumulator Mode (High Speed), 100 Hz 2 Current Mode not supported 2 6 4
Analog Output (AO) Analog Output, Voltage Mode, 0–10 VDC Analog Current Mode, 4–20 mA 2 External Power only 3 6 4
Binary Output (BO) 24 VAC Triac 2 4 4 4
Configurable Output (CO) Analog Output, Voltage Mode, 0–10 VDC Binary Output Mode, 24 VAC Triac 2 – SPDT and 3 – SPST linevoltage relays, 1/4 hp 120 VAC, 1/2 hp 240 VAC
Relay Output (RO) RO: Single-Pole, Double-Throw (SPDT)

RO: Single-Pole, Single-Throw (SPST)

Communication protocol FAC2513, FAC2611, FAC2612, FAC3613 ⇒ BACnet MS/TP, N2, or Zigbee wireless with add-on modules
FAC4911 ⇒ BACnet/SC or BACnet/IP
Engines supported FAC2513, FAC2611, FAC2612, FAC3613 ⇒ All Model types. Refer to the Network Engines Product Bulletin (LIT-12012138) for details
FAC4911 ⇒ All Model types; however, certain restrictions apply. For more information, refer to the footnotes in the Network Engine Hardware Limitations table in the Metasys System Configuration Guide (LIT-12011832) for details
Modular jacks All models ⇒ 6-pin SA Bus Modular Port supports one communicating sensor. Or you can wire up to four communicating sensors to the SA Bus Terminal Block. They cannot be used at the same time
FAC2611, FAC2612, FAC3613 ⇒ 6-pin FC Bus for tool support

 

FAC series information

Product Code Number Description
MS-FAC2611-0 17-Point Advanced Application Field Equipment Controller with 6 UI, 2 BI, 4 CO, 3 BO, and 2 AO; 24 VAC; SA Bus; FC Bus; Integral Real-time Clock
MS-FAC2612-1 18-Point Advanced Application Field Equipment Controller with 5 UI, 4 BI, 4 CO, 2 SPDT and 3 SPST Line-Voltage ROs 1/4 hp 120 VAC, 1/2 hp 240 VAC; 24 VAC; SA Bus; FC Bus; Integral Real−time Clock
MS-FAC2612-2 18-Point Advanced Application Field Equipment Controller with 5 UI, 4 BI, 4 CO, 2 SPDT and 3 SPST Line-Voltage ROs, 1/4 hp 120 VAC, 1/2 hp 240 VAC; 100–240 VAC; SA Bus; FC Bus; Integral Real-time Clock
MS-FAC3613-0 26-Point Advanced Application Field Equipment Controller with 8 UI, 6 BI, 6 BO, and 6 AO; 24 VAC; SA Bus; FC Bus; Integral Real-time Clock; Fast Persistence
MS-FAC4911-0 28-Point Advanced Application Field Equipment Controller with 10 UI, 6 BI, 4 BO, 4 AO, and 4 CO; 24 VAC; SA Sensor Port; Integral Real-time Clock; 2 Ethernet Ports for BACnet/SC or BACnet/IP Communications

 

FAC series

Information Description
Product Code Numbers MS-FAC2513-0: 16-Point FAC with Integral Real-Time Clock and 24 VAC Supply Power

MS-FAC2611-0: 17-Point FAC with Integral Real-Time Clock and 24 VAC Supply Power

MS-FAC2612-1: 18-Point FAC with Integral Real-Time Clock and 24 VAC Supply Power

MS-FAC2612-2: 18-Point FAC with Integral Real-Time Clock and 100–240 VAC Supply Power

MS-FAC3613-0: 26-Point FAC with Integral Real-Time Clock and 24 VAC Supply Power with Fast Persistence

MS-FAC4911-0: 28-Point FAC with Integral Real-Time Clock and 24 VAC Supply Power

 

Smoke Control Models:
MS-FAC2611-0U: 17-Point FAC with Integral Real-Time Clock and 24 VAC Supply Power

MS-FAC2612-1U: 18-Point FAC with Integral Real-Time Clock and 24 VAC Supply Power

Communications Protocol MS-FAC2513-0, MS-FAC2611-0, MS-FAC2612-1, MS-FAC2612-2, and MS-FAC3613-0: BACnet MS/TP, N2

MS-FAC4911-0: BACnet/SC or BACnet/IP

Engines Supported MS-FAC2513-0, MS-FAC2611-0, MS-FAC2612-1, MS-FAC2612-2, and MS-FAC3613-0: All Model types. Some NIE models support MS/TP and N2 devices. Refer to the Network Engines Product Bulletin (LIT-12012138) for details

MS-FAC4911-0: All Model types; however, certain restrictions apply. Refer to the footnotes in the Network Engine Hardware Limitations table of the Metasys System Configuration Guide (LIT 12011832) for details

Power Requirement MS-FAC2513-0, MS-FAC2611-0, MS-FAC2612-1, MS-FAC3613-0, and MS-FAC4911-0: 24 VAC (nominal, 20 VAC minimum/30 VAC maximum), 50/60Hz, Power Supply Class 2 (North America), SELV (Europe)

MS-FAC2612-2: 100–240 VAC 50/60 Hz

Power Consumption MS-FAC2513-0, MS-FAC2611-0, MS-FAC3613-0, and MS-FAC4911-0: 14 VA maximum

MS-FAC2612-1: 30 VA maximum

MS-FAC2612-2: 40 VA maximum

Ambient Conditions Operating: 0 to 50°C (32 to 122°F), 10 to 90% RH noncondensing; Pollution Degree 2

Storage: -40 to 80°C (-40 to 176°F), 5 to 95% RH noncondensing

Device addressing for BACnet MS/TP Decimal address set using dip switches: valid controller device addresses 4-127
Device addressing for N2 Decimal address set using dip switches: valid controller device addresses 1-254
Controller Number for Ethernet controller 3 rotary switches to assign a unique number for each controller to physically identify the controller and relate it to the building drawings; valid controller numbers 0-999
Communications Bus RS-485, field selectable between BACnet MS/TP and N2 communications on certain models:
• 3-wire FC Bus between the supervisory controller and field controllers
• 4-wire SA Bus between field controller, network sensors, and other sensor/actuator devices, includes a lead to source 15 VDC supply power (from field controller) to bus devicesMS-FAC4911-0:
• BACnet/SC or BACnet/IP over Ethernet cable
• 4-wire SA Bus between field controller, network sensors, and other sensor/actuator devices, includes a lead to source 15 VDC supply power (from field controller) to bus devices
Processor MS-FAC2611-0, MS-FAC2612-1, and MS-FAC2612-2 : H8SX/166xR Renesas® microcontroller

MS-FAC2513-0 and MS-FAC3613-0: RX631 32-Bit Renesas microcontroller

MS-FAC4911-0: RX63N 32-Bit Renesas microcontroller

Memory MS-FAC2611-0, MS-FAC2612-1, and MS-FAC2612-2: 4 MB Flash Memory and 1 MB RAM

MS-FAC2513-0 and MS-FAC3613-0: 16 MB Flash Memory and 8 MB SDRAM

MS-FAC4911-0: 16 MB Flash Memory and 8 MB RAM

Real-Time Clock Backup Power Supply Super capacitor maintains power to the onboard real-time clock for a minimum of 72 hours when supply power to the controller is disconnected
Input and Output Capabilities

MS-FAC2513-0

4 – Universal Inputs: Defined as 0–10 VDC, 0–600k ohm, or Binary Dry Contact
6 – Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/Accumulator Mode
2 – Analog Outputs: Defined as 0–10 VDC
2 – Binary Outputs: Defined as 24 VAC Triac (external power source only)
2 – Configurable Outputs: Defined as 0–10 VDC or 24 VAC Triac BO

 

MS-FAC2611-0

6 – Universal Inputs: Defined as 0–10 VDC, 4–20 mA, 0–600k ohm, or Binary Dry Contact
2 – Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/Accumulator Mode
2 – Analog Outputs: Defined as 0–10 VDC or 4–20 mA
3 – Binary Outputs: Defined as 24 VAC Triac (selectable internal or external source power)
4 – Configurable Outputs: Defined as 0–10 VDC or 24 VAC Triac BO

 

MS-FAC2612-1 and MS-FAC2612-2

5 – Universal Inputs: Defined as 0–10 VDC, 4–20 mA, 0–600k ohm, or Binary Dry Contact
4 – Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/Accumulator Mode
4 – Configurable Outputs: Defined as 0–10 VDC or 24 VAC Triac BO
2 – Relay Outputs (Single-Pole, Double-Throw): UL 916: 1/4 hp 120 VAC, 1/2 hp 240 VAC; 360 VA Pilot Duty at 120/240 VAC (B300); 3 A Non-inductive 24–240 VAC; EN 60730: 6 (4) A N.O. or N.C. only
3 – Relay Outputs (Single-Pole, Single-Throw): UL 916:1/4 hp 120 VAC, 1/2 hp 240 VAC; 360 VA Pilot Duty at 120/240 VAC (B300); 3 A Non-inductive 24–240 VAC; EN 60730: 6 (4) A N.O. or N.C. only

 

MS-FAC3613-0

8 – Universal Inputs: Defined as 0–10 VDC, 4–20 mA, 0–600k ohms, or Binary Dry Contact
6 – Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/Accumulator Mode
6 – Binary Outputs: Defined as 24 VAC Triac (external power source only)
6 – Analog Outputs: Defined as 0–10 VDC or 4–20 mA

 

MS-FAC4911-0

10 – Universal Inputs: Defined as 0–10 VDC, 0–600k ohms, or Binary Dry Contact
6 – Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/Accumulator Mode
4 – Binary Outputs: Defined as 24 VAC Triac (external power source only)
4 – Analog Outputs: Defined as 0–10 VDC or 4–20 mA
4 – Configurable Outputs: Defined as AO mode , 0–10 VDC or BO mode, 24 VAC Triac

Analog Input (AI)/ Analog Output (AO) Resolution and Accuracy Analog Input: 15-bit resolution

Analog Output: 15-bit resolution, +/- 200 mV accuracy in 0–10 VDC applications

Terminations

MS-FAC2513-0

Input/Output: Fixed Screw Terminal Blocks

FC Bus, SA Bus and Supply Power: 3-wire and 4-wire Pluggable Screw Terminal Blocks

SA Bus Port: RJ-12 6-pin Modular Jacks

 

MS-FAC2611-0 and MS-FAC3613-0

Input/Output: Fixed Screw Terminal Blocks

FC Bus, SA Bus and Supply Power: 3-wire and 4-wire Pluggable Screw Terminal Blocks

FC Bus and SA Bus Port: RJ-12 6-pin Modular Jacks

 

MS-FAC2612-1 and MS-FAC2612-2

Input/Output: Pluggable Screw Terminal Blocks

FC Bus, SA Bus and Supply Power: 3-wire and 4 wire Pluggable Screw Terminal Blocks

FC Bus and SA Bus Port: RJ-12 6-pin Modular Jacks

 

MS-FAC4911-0

Input/Output: Fixed Screw Terminal Blocks

SA Bus and Supply Power: 3-wire and 4-wire Pluggable Screw Terminal Blocks

SA Bus Port: RJ-12 6-pin Modular Jacks

Mounting Horizontal on single 35 mm DIN rain mount (preferred), or screw mount on flat surface with three integral mounting clips on controller
Housing Enclosure material: ABS and polycarbonate UL94 5VB, self-extinguishing; Plenum-rated Protection

Class: IP20 (IEC529) (except the FAC2612 controller)

Dimensions (Height x Width x Depth) MS-FAC2513-0: 150 x 164 x 48 mm (5-7/8 x 6-7/16 x 1-7/8 in.) including terminals and mounting clips

MS-FAC2611-0: 150 x 190 x 53 mm (5-7/8 x 7-1/2 x 2-1/8 in.) including terminals and mounting clips

MS-FAC2612-x: 150 x 164 x 53 mm (5-7/8 x 6-7/16 x 2-1/8 in.) including terminals and mounting clips

MS-FAC3613-0 and MS-FAC4911-0: 150 x 220 x 57.5 mm (5-7/8 x 8-3/4 x 2-3/8 in.) including terminals and mounting clips

Weight 0.5 kg (1.1 lb)

 


Catalog PDF: FAC Controllers_Catalog_Johnson Controls_EN_US

Price on request